Heart sounds are the sounds heard when a stethoscope is placed on the chest. Each heartbeat produces two of them: S1, at the start of ventricular contraction, caused by the closing of the mitral and tricuspid valves, and S2, at the end of ejection, caused by the closing of the aortic and pulmonary valves. Together they give the familiar “lub-dub”: S1 is slightly longer and lower, S2 shorter and sharper. In French they are written B1 and B2.
Discover FizziQ
How to measure it in class
A smartphone microphone can act as a simple stethoscope. With FizziQ’s Amplitude (oscilloscope view) instrument, you see the sound signal as a function of time and can pick out the two sounds of each cycle.
Steps:
- Sit or lie down in a very quiet room and wait a minute for your breathing to settle.
- Open FizziQ and choose the microphone’s Amplitude (oscilloscope view) instrument, with the longest time window (10 s).
- Press the bottom edge of the phone, where the microphone is, firmly against the skin, left of the breastbone, between the 4th and 5th spaces between the ribs.
- Start recording and stay still for 10 to 15 seconds, breathing gently or briefly holding your breath.
- On the trace, look for pairs of bursts that repeat: the first of each pair is S1, the second S2.
- Measure the time between two successive S1 sounds, which is the period T of the cardiac cycle, and compute the heart rate HR = 60 / T.
- Also measure the S1-S2 interval and the following S2-S1 interval, then repeat the recording after about ten squats and compare.
Heart sounds are faint and very low-pitched. Smartphone microphones are tuned for speech and attenuate these low frequencies, so depending on the model and on where you press, the signal may be clear, weak or missing altogether. Firm contact and complete silence make a big difference.
Scientific activities on this topic
Three activities follow the cardiac cycle with a smartphone, through sound, movement and light.
- Cardiac auscultation by mic: turn a smartphone into a stethoscope and record S1 and S2
- Heart rate by accelerometer: detect heartbeats from the tiny movements of the chest
- Photoplethysmography of a finger: measure your pulse with the camera and flash
Learn more
Where S1 and S2 come from
The heart has four valves that keep blood flowing in one direction. The atrioventricular valves (mitral on the left, tricuspid on the right) separate the atria from the ventricles. The semilunar valves (aortic and pulmonary) separate the ventricles from the great arteries.
When the ventricles start to contract, their pressure rises above that of the atria and the mitral and tricuspid valves snap shut. That is S1, which marks the start of systole. When ejection ends and the ventricles relax, their pressure falls below that of the aorta and pulmonary artery, and the semilunar valves close in turn. That is S2, which marks the start of diastole.
The sound is not simply the valve leaflets slapping together. Closure stops the blood abruptly, and this sudden deceleration sets the valves, the column of blood and the heart walls vibrating. These vibrations travel to the chest wall, where they can be heard.
Systole and diastole on the recording
The gap between S1 and S2 is systole, while blood is being ejected. The gap between S2 and the next S1 is diastole, while the ventricles refill. At rest, around 75 beats per minute, a cycle lasts 0.8 s, of which roughly 0.3 s is systole and 0.5 s diastole. As the heart speeds up, it is mainly diastole that gets shorter: the long gap shrinks towards the short one and the “lub-dub, lub-dub” rhythm sounds more even.
Why S1 is lower than S2
The semilunar valves close against the pressure of the great arteries, which pulls them taut. They vibrate faster and more briefly, giving a sharper, slightly higher S2. S1 involves the large atrioventricular valves and the mass of the ventricles, and lasts a little longer, around 0.1 to 0.15 s. In both cases most of the energy lies at low frequencies, roughly 20 to 150 Hz for S1 and a little higher for S2. These are faint, low-pitched sounds, which phone microphones, designed for speech, struggle to pick up.
Auscultation
René Laennec invented the stethoscope in 1816 at the Necker hospital in Paris: a simple rolled-up tube of paper let him hear a patient’s heart better than by putting his ear to her chest. A modern stethoscope has two sides. The diaphragm transmits relatively high frequencies such as S1, S2 and most murmurs, while the bell, placed lightly on the skin, favours very low sounds.
Doctors listen at several points on the chest. S1 is loudest at the apex of the heart, below the left nipple (mitral area). S2 is loudest at the top of the chest on either side of the breastbone, in the 2nd intercostal space (aortic and pulmonary areas). In healthy young people S2 often splits on breathing in: the pulmonary valve then closes a few hundredths of a second after the aortic valve.
Other sounds can occur. S3, at the start of ventricular filling, is common and normal in children and teenagers. S4, linked to atrial contraction, is normally not audible in a healthy person. Murmurs are longer sounds caused by turbulent blood flow; many are harmless in children, but interpreting them is a doctor’s job.
An important note
FizziQ is a teaching tool, not a medical device. Recording heart sounds with a smartphone is a way to understand the cardiac cycle and measure a period. It cannot detect a murmur or any abnormality, and it is no substitute for examination by a doctor.
Formula
Heart rate follows from the period of the cycle, measured between two successive S1 sounds:
HR = 60 / T
where:
- HR: heart rate (beats per minute)
- T: period of the cardiac cycle, time between two consecutive S1 sounds (s)
The durations of systole and diastole can be read from the same recording:
t_systole = t(S2) - t(S1)
t_diastole = T - t_systole
where:
- t(S1), t(S2): times at which S1 and S2 begin in the same cycle (s)
- t_systole: duration of ventricular systole, the S1-S2 interval (s)
- t_diastole: duration of diastole, the S2-S1 interval (s)
Application examples
-
On a 10 s recording, the first and thirteenth S1 sounds are 9.6 s apart, so 12 full cycles: T = 9.6 / 12 = 0.80 s, giving HR = 60 / 0.80 = 75 bpm.
-
In the same recording, S2 comes 0.30 s after S1: systole lasts 0.30 s and diastole 0.80 - 0.30 = 0.50 s.
-
After exercise the period drops to 0.50 s (120 bpm): systole has shortened only a little, to about 0.25 s, while diastole has gone from 0.50 s to about 0.25 s, half its resting value.
-
Heart sounds and the finger photoplethysmography signal have the same period, but the pulse reaches the finger slightly after S1, because the pressure wave takes time to travel along the arteries.
-
Electronic stethoscopes record and amplify heart sounds, filter out background noise and can display the resulting trace, called a phonocardiogram.
FAQ
Q: What do S1 and S2 mean? A: S stands for “sound” and the number gives its order in the cycle. S1 is the first sound, when the mitral and tricuspid valves close at the start of systole. S2 is the second, when the aortic and pulmonary valves close at the start of diastole. French textbooks call them B1 and B2, for “bruit”.
Q: How can I tell S1 from S2 on a recording? A: By the rhythm. At rest, the gap after S1 is shorter than the gap after S2, so the first sound of a close pair is S1. You can also check against your pulse: it is felt at the wrist just after S1.
Q: Why do I sometimes get no signal at all with my phone? A: Heart sounds are faint and very low-pitched, while a phone microphone is designed for speech and often filters out low frequencies. Skin rubbing, breathing and background noise can then hide the signal completely. This is a normal experimental outcome and depends on the phone model.
Q: Is an extra sound besides S1 and S2 a cause for concern? A: Not necessarily: a third sound is common in healthy young people, and many childhood murmurs are harmless. Only a doctor can interpret auscultation. A classroom recording made with a smartphone is not enough to draw any conclusion.
Q: Is the heart rate from the sounds the same as from the pulse? A: Yes, normally. Each cycle produces one S1, one S2 and one pulse wave, so all three methods give the same rate. Only the timing differs, since the pulse takes a moment to reach the wrist or finger.
Related concepts
Photoplethysmography - Human Physiology - Microphone - Oscillogram - Period - Measurement Noise - Sound Signal Propagation - Accelerometer